www.mass.dk

Sharing what I know...

  • Increase font size
  • Default font size
  • Decrease font size
Home Netbackup Quick hints Netbackup Fibre Transport Layer status code 40

Netbackup Fibre Transport Layer status code 40

If you encounter status code 40 - "network connection broken" using Netbackup Fibre Transport Layer (FTL)  on Windows 2003 SP2 and you see event id 129 - Source ql2300 in the event log

and vxlogview report some or all of the errors below for Fibre Transport service :

CHECK CONDITION
    Valid                    = false
    Error Code                = 0x70
    Segment Number (0)        = 0x0
    Mark                    = false
    EOM                    = false
    ILI                    = false
    Sense Key                = 0x9
    Information Bytes MSB1            = 0x0
    Information Bytes MSB0            = 0x0
    Information Bytes LSB1            = 0x0
    Information Bytes LSB0            = 0x0
    Additional Sense Length (0xE)        = 0x8
    Command Specific Information Bytes MSB1    = 0x0
    Command Specific Information Bytes MSB0    = 0x0
    Command Specific Information Bytes LSB1    = 0x0
    Command Specific Information Bytes LSB0    = 0x0
    Additional Sense Code            = 0x80
    Additional Sense Code Qualifier        = 0x2
    Field Replaceable Unit Code        = 0x0
    SKSV                    = 0x0
    C/D                    = 0x0
    BPV                    = 0x0
    Bit Pointer                = 0x0
    Field Pointer/Drive Error Code MSB    = 0x0
    Field Pointer/Drive Error Code LSB    = 0x0
    Command Descriptor Block (Hex Values, Cdb[0]...Cdb[15])   3b 2 1 0 0 c1 4 0 0 0 0 0 0 0 0 0

10/20/2009 14:19:50.734 [BackupThread] 1272: Pipe ID = 1 ftseq 243 length 262144
10/20/2009 14:20:26.954 [BackupThread] 1272: Pipe ID 1 Exceeded MAX_SEM_TIMEOUT_COUNT at ftseq 244
10/20/2009 14:20:26.954 [BackupThread] 1272: Pipe ID 1 wait count source 0 dest 0 write ahead wait count 0 ioctl error count 5 Thread bytes 63963136 Total bytes 63963136
10/20/2009 14:20:26.954 [BackupThread] 1272: Pipe ID 1 stopped at ftseq 244 with 16 full buffers offlining device, Device name \\.\Scsi4:0.0.0
10/20/2009 14:20:26.954 [OpenPTDeviceHandle] \\.\Scsi4:0.0.0 m_HandleOpenCount 2
10/20/2009 14:20:26.954 [ValidateOpenDevice] DeviceInquiry succeeded; \\.\Scsi4:0.0.0
10/20/2009 14:20:26.954 [ClosePTDeviceHandle] \\.\Scsi4:0.0.0 m_HandleOpenCount 1
10/20/2009 14:20:26.969 [PipeCleanupTaskThread] (4712) PTT_PipeShutdown

Set the data rate to a fixed speed and the connect option to "Point to Point only".

 

 

Last Updated on Friday, 11 June 2010 12:47